参考文献/References:
References
[1] ASHRAE. 2001 ASHRAE Handbook: Fundamentals[M]. Atlanta: American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., 2001: 26.2-26.3.
[2] 马仁民. 置换通风的通风效率及其微热环境评价[J].暖通空调, 1997, 27(4): 1-6.
MA Renmin. Displacement ventilation effectiveness and evaluation of the micro thermal environment[J]. Heating Ventilating & Air Conditioning, 1997, 27(4): 1-6.
[3] 李强民. 置换通风原理、设计及应用[J]. 暖通空调,2000, 30(5): 41-46.
LI Qiangmin. Displacement ventilation: principles, design and applications[J]. Heating Ventilating & Air Conditioning, 2000, 30(5): 41-46.
[4] HAMILTON S, ROTH K W, BRODRICK J. Displacement ventilation[J]. ASHRAE Journal, 2004, 46(9): 56-58.
[5] KARIMIPANAH T, SANDBERG M, AWBI H B. A comparative study of different air distribution systems in a classroom[C]//Proceedings of the ROOMVENT 2000, Reading, UK, 2000, Vol. II: 1013-1018.
[6] MELIKOV A K, RADIM C, MILAN M. Personalized ventilation: evaluation of different air terminal devices[J]. Energy and Building, 2002, 34(8): 829-836.
[7] 林章, 周天泰, 曾志宽. 层式通风—高温空调下的出路[J]. 化工学报, 2008, 59(S2): 235-241.
LIN Zhang, CHOW T T, TSANG C. Ventilation system for higher room temperature setting[J]. Journal of Chemical Industry and Engineering, 2008, 59(S2): 235-241.
[8] CAO G Y, SIR?N K, KILPEL?INEN S. Modeling and experimental study of performance of the protected occupied zone ventilation[J]. Energy and Building, 2014, 68(Part A): 515-531.
[9] 李安桂, 邱少辉, 王国栋. 竖壁贴附射流空气湖模式通风系统:中国, 200810017349.0 [P]. 2008-01-21.
LI Angui, QIU Shaohui, WANG Guodong. A downward directed vertical wall jet ventilation system based on air lake model: China, 200810017349.0 [P]. 2008-01-21.
[10] LI Angui, YIN Haiguo, ZHANG Wangda. A novel air distribution method-Principles of air curtain ventilation[J]. International Journal of Ventilation, 2012,10(4): 383-390.
[11] 李安桂, 尹海国, 陶鹏飞. 一种出风均匀且风口可调式静压箱[P]. 中国, 201010549210.8, 2012.07.25.
LI Angui, YIN Haiguo TAO Pengfei. A plenum chamber with uniform air supply and adjustable air outlet[P]. P.R. China, 201010549210.8, 2012.07.25.
[12] THORSHAUGE J. Air-velocity fluctuations in the occupied zone of ventilated spaces[J], ASHRAE Transactions, 1982, 88(2): 753-764.
[13] RAJARATNAM N. Turbulent Jets[M]. Amsterdam: Elsevier, 1976: 211-213.
[14] ASHRAE. 1993 ASHRAE Handbook: Fundamentals[M]. Atlanta: American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., 1993.
[15] CHO Y J, AWBI H B, KARIMIPANAH T. Theoretical and experimental investigation of wall confluent jets ventilation and comparison with wall displacement ventilation[ J]. Building and Environment, 2008, 43(6): 1091-1100.
[16] KARIMIPANAH T, AWBI H B. Theoretical and experimental investigation of impinging jet ventilation and comparison with wall displacement ventilation[J]. Building and Environment, 2002, 37(12): 1329-1342.
[17] CAO G. Modelling the attached plane jet in a room[D]. PhD thesis, Finland: Helsinki University of Technology, 2009.
[18] F?RTHMANN E. Turbulent jet expansion[R]. Washington, D.C.: National Aeronautics and Space Administration, 1934: No. TM-789.
[19] VERHOFF A. The two-dimensional turbulent wall jet without an external free stream[R]. Princeton: Princeton University, 1963: No. 626.
[20] SCHWARZ W H, COSART W P. The two-dimensional turbulent wall jet[J]. Journal of Fluid Mechanics, 1961, 10(4): 481-495.
[21] BELTAOS S, RAJARATNAM N. Plane turbulent impinging jets[J]. Journal of Hydraulic Research, 1973, 11(1): 29-59.
相似文献/References:
[1]狄育慧,王善聪.利用Airpak模拟室内气流组织的误差分析[J].西安建筑科技大学学报:自然版,2013,45(01):73.[doi:10.15986/j.1006-7930.2013.01.011]
DI Yu-hui,WANG Shan-cong.Error analysis of simulation of indoor airflow organizations with Airpak[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2013,45(06):73.[doi:10.15986/j.1006-7930.2013.01.011]
[2]狄育慧,徐子龙,邓保顺.火车站候车厅不同回风形式的热环境研究[J].西安建筑科技大学学报:自然版,2014,46(05):742.[doi:10.15986/j.1006-7930.2004.05.022]
DI YuhuiXU ZilongDENG Baoshun.Study on different forms of return air indoor thermal environment in the large space of Xi’an Railway Station[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2014,46(06):742.[doi:10.15986/j.1006-7930.2004.05.022]
[3]李安桂,陈 强,尹海国,等.十三陵电站坝体廊道通风动态换热节能设计理论基础研究[J].西安建筑科技大学学报:自然版,2015,47(06):874.[doi:10.15986/j.1006-7930.2015.06.021]
LI AnguiCHEN QiangYIN HaiguoGAO Ran.Study on dynamic heat transfer and basic theory of energy saving design of Shisanling Hydropower Station based on the dam tunnel ventilation[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2015,47(06):874.[doi:10.15986/j.1006-7930.2015.06.021]
[4]李安桂,李明明.小微空间通风空调贴附式气流组织的有效性研究[J].西安建筑科技大学学报:自然版,2016,48(01):115.[doi:10.15986/j.1006-7930.2016.01.019]
LI Angui,LI Mingming.Research on the effectiveness of air curtain ventilation air distribution for small micro–space[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2016,48(06):115.[doi:10.15986/j.1006-7930.2016.01.019]
[5]李安桂,刘旺兴,要聪聪,等.竖壁贴附射流加导流板呼吸区送风气流组织CFD及试验研究[J].西安建筑科技大学学报:自然版,2016,48(05):738.[doi:10.15986/j.1006-7930.2016.05.020]
LI Angui,LIU Wangxing,YAO Congcong,et al.CFD and the experimental study of air distribution in the breathing zone based on air curtain ventilation with deflector[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2016,48(06):738.[doi:10.15986/j.1006-7930.2016.05.020]
[6]黄 翔,李婷婷,刘凯磊,等.乌鲁木齐某数据中心热环境分析及气流组织优化研究[J].西安建筑科技大学学报:自然版,2019,51(01):104.[doi:10.15986/j.1006-7930.2019.01.016]
LI Tingting,HUANG Xian,LIU Kailei,et al.Thermal environment analysis and air distribution optimization for a Data Room in Urumqi[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2019,51(06):104.[doi:10.15986/j.1006-7930.2019.01.016]
[7]尹海国,李安桂,刘志永,等.方型柱面贴附置换通风模式影响因素分析[J].西安建筑科技大学学报:自然版,2016,48(04):591.[doi:10.15986/j.1006-7930.2016.04. 022]
YIN Haiguo,LI Angui,LIU Zhiyong,et al.Analysis on influence factors of square column attached displacementventilation mode[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2016,48(06):591.[doi:10.15986/j.1006-7930.2016.04. 022]