[1]申健,李安桂,杨长青,等.印刷车间冬季分区域空调气流组织效果测试研究[J].西安建筑科技大学学报(自然科学版),2017,49(02):265-270.[doi:1006-7930(2017)02-0265-06 10.15986/j.1003-7930.]
 SHEN Jian LI Angui YANG Changqing ZHANG YingZHAO Yujiao.Field test on air distribution of multi-zone air-conditioning in a large[J].J. Xi’an Univ. of Arch. & Tech.(Natural Science Edition),2017,49(02):265-270.[doi:1006-7930(2017)02-0265-06 10.15986/j.1003-7930.]
点击复制

印刷车间冬季分区域空调气流组织效果测试研究()
分享到:

西安建筑科技大学学报(自然科学版)[ISSN:1006-7930/CN:61-1295/TU]

卷:
49
期数:
2017年02期
页码:
265-270
栏目:
出版日期:
2017-04-28

文章信息/Info

Title:
Field test on air distribution of multi-zone air-conditioning in a large
文章编号:
1006-7930(2017)02-0265-06
作者:
申健李安桂杨长青张莹赵玉娇
(1.西安建筑科技大学环境与市政工程学院,陕西 西安 710055;2. 西安科技大学能源学院,陕西 西安 ,710054)
Author(s):
SHEN Jian1 LI Angui1 YANG Changqing1 ZHANG Ying1ZHAO Yujiao2
(1. School of Environmental and Municipal Engineering, Xian Univ. of Arch. & Tech. , Xian 710055, China; 2. School of Energy and Resource, Xian Univ. of Sci. and Tech. , Xian 710054, China)
Keywords:
large space warm air heating thermal stratification air distribution field test [1][2-3][4-][7][9]
分类号:
TU83
DOI:
1006-7930(2017)02-0265-06 10.15986/j.1003-7930.
文献标志码:
A
Abstract:
There is a positive vertical temperature gradient between the floor and the ceiling, especially in winter, due to the influence of buoyancy forces of warm air. During the heating season, the presence of a warm air layer below the ceiling will increase the heat losses. In order to keep people in the occupied zone comfort, more heat would be required. This paper measures temperature profiles and thermal stratification in a large printing house whether with air conditioning heating or without air conditioning. The results show that the air distribution conducted in the printing house prevents the thermal stratification effectively with a good control of humidity, which enhances the efficiency of the warm air utilization

参考文献/References:

References
[1] 范存养.国外大空间建筑的空调设计.暖通空调[J],1996,26(4).
FAN Cunyang. abroad[J]. HV&AC,1996,26(4).[2] SAID M N A, MACDONALD R A, DURRANT G C. Measurement of thermal stratification in large single-cell buildings[J]. Energy & Buildings, 1996, 24(2):105-115.
[3] CHOW W K, FUNG W Y, WONG L T. Preliminary studies on a new method for assessing ventilation in large spaces[J]. Building & Environment, 2002, 37(2):145-152.
[4] CIBSE guide B : Heating, ventilating, air conditioning and refrigeration[M]. Chongqing: Chongqing Univ. Press, 2008.
[5] 胡万玲,管勇.空调送风角对冬季办公室气流组织影响的数值研究[J]兰州交通大学学报,2009,28(3):151154.

HU Wanling, GUAN Yong. Numerical simulation of air field with different angles of wall mounted[J]. J. of Lanzhou Jiaotong Univ.,2009,28(3):151154.


[6]RAHIMI M, TAJBAKHSH K. Reducing temperature stratification using heated air recirculation for respectively thermal energy saving[J]. Energy and Building, 2011, 43(10): 26562661.


[7]辛峰,杨燕慧,杨德福.高大空间分层供暖室内气流的数值模拟研究[J]. 建筑节能,2009(4):2123.

XIN Feng, YANG Yanhui, YANG Defu. Numerical simulation research on airdistribution in a stratified heating large space[J].Heating ventilation & equipment,2009(4):2123.