[1]刘秋新,童 亮,包 阔.地埋管绝热措施下的换热强度[J].西安建筑科技大学学报(自然科学版),2016,48(05):751-754.[doi:10.15986/j.1006-7930.2016.05.022]
 LIU Qiuxin,TONG Liang,BAO Kuo.Heat transfer intensity of ground heat exchanger under adiabatic measures[J].J. Xi’an Univ. of Arch. & Tech.(Natural Science Edition),2016,48(05):751-754.[doi:10.15986/j.1006-7930.2016.05.022]
点击复制

地埋管绝热措施下的换热强度()
分享到:

西安建筑科技大学学报(自然科学版)[ISSN:1006-7930/CN:61-1295/TU]

卷:
48
期数:
2016年05期
页码:
751-754
栏目:
出版日期:
2016-10-31

文章信息/Info

Title:
Heat transfer intensity of ground heat exchanger under adiabatic measures
文章编号:
1006-7930(2016)05-0751-04
作者:
刘秋新童 亮包 阔
(武汉科技大学城市建设学院,湖北 武汉 430070)
Author(s):
LIU Qiuxin TONG Liang BAO Kuo
(Urban Construction College, Wuhan University of Science and Technology, Wuhan 430070)
关键词:
地源热泵单位井深换热量保温数值模拟
Keywords:
ground source heat pump transferring heat per unit of borehole depth thermal insulation numerical simulation
分类号:
TU831.6
DOI:
10.15986/j.1006-7930.2016.05.022
文献标志码:
A
摘要:
地源热泵系统换热效果所受到的影响因素很多,地源热泵换热量的大小是反映系统换热性能优劣的重要参数.通过CFD数值模拟软件分析了单U地埋管保温、不保温和保温长度不同及不同流量下的换热情况,得出了地埋管的单位井深换热量是随着流量的增大而增大,保温地埋管换热能力要高于非保温管,且保温层深度要适宜的结论.同时,结合实际工程实测数据进行对比分析,验证了模型及数值模拟结果的正确性.
Abstract:
There are many factors affecting the heat transfer effects for ground source heat pump systems . The heat exchange amount of ground source heat pump(GSHP) is an important index to reflect heat transfer performance. By using CFD software, the heat exchange capability of single-U buried pipe under different flow rate and the rmal insulation conditions is analyzed. A conclusion is derived there from that the heat exchange amount per unit depth of well increases with the flow rate, the heat exchange capability of thermal insulation buried pipe surpasses non-thermal insulation pipe and the depth of Insulation pipe should be appropriately chosen. Furthermore, the validity of the model and simulation result is verified through comparison with project measured data.

参考文献/References:

[1] 仉安娜, 唐远明. 环保节能地源热泵技术应用研究[J]. 环境保护与循环经济, 28(12): 34-37.

JI Anna, TANG Yuanming. Application of environmental protection and energy saving ground source heat pump technology[J]. Environmental Protection and Recycling Economy, 28(12): 34-37.

[2] 杨惜春. 气候资源的法律概念及其属性探讨[J]. 气象与环境学报, 2007, 23(1): 39-44.

YANG Xichun. A study on the legal concepts and attributes of climate resources[J]. Journal of Meteorology and Environment. 2007, 23(1): 39-44.

[3] 徐伟, 张时聪. 中国地源热泵技术现状及发展趋势[J]. 太阳能, 2007(3): 11-14.

XU Wei, ZHANG Shichong. China’s ground source heat pump technology and development trend[J]. Solar Energy, 2007(3): 11-14.

[4] 宋小飞, 温冶, 司俊龙. 地源热泵U型管地下换热器的CFD数值模拟[J]. 北京科技大学报, 2007, 29(3): 329-333.

SONG Xiaofei, WEN Ye, SI Junlong. Numerical simulation of U-tube underground heat exchanger for ground source heat pump[J]. Journal of Beijing University of Science And Technology, 2007, 29(3): 329-333.

[5] 中华人民共和国建设部. 地源热泵系统工程技术规范: GB-50366-2009版[S]. 北京: 中国建筑工业出版社, 2009.

Ministry of Construction of the People’s Republic of China. Ground-source Heat Pump System Engineering Specification: GB-50366 -2009[S]. Beijing: China Architecture and Building Press, 2009.

[6] 唐志伟, 时晓燕, 黄俊惠, 等. 地源热泵U型管地下换热器的数值模拟[J]. 北京工业大学学报, 2006, 32(1): 62-66.

TANG Zhiwei, SHI Xiaoyan, HUANG Junhui, et al. Numerical simulation of U-tube underground heat exchanger for ground source heat pump[J]. Journal of Beijing University of Technology, 2006, 32(1): 62-66.

[7] 方肇洪, 刁乃仁. 地热换热器的传热分析[J]. 建筑热能通风空调, 2004, 23(1): 11-20.

FANG Zhaohong, DIAO Nairen. Heat transfer analasys of geothermal heat exchanger[J]. Building Energy & Environment, 2004, 23(1): 11-20.

[8] 刘秋新, 韩进能, 高春雪, 等. 地源热泵耦合地埋管换热计算若干问题的研究[J]. 低温与超导, 2008, 36(5): 64-68.

LIU Qiuxin, HAN Jinneng, GAO Chunxue et al. Study on several problems of heat transfer calculation of ground source heat pump coupled ground buried pipes[J]. Low Temperature and Superconductivity , 2008, 36(5): 64-6 8.

备注/Memo

备注/Memo:
基金项目:武汉市城乡建设委员会项目(201305)
收稿日期:2015-11-07 修改稿日期:2016-10-14
作者简介:刘秋新(1956-),男,博士,教授,研究方向为工业通风与暖通空调.E-mail: 125730568@qq.com