[1]杨 磊,陈 雁,贾少东,等.无柱大跨地铁车站抗震性能试验与分析[J].西安建筑科技大学学报(自然科学版),2020,52(05):672-683.[doi:10.15986j.1006-7930.2020.05.009 ]
 YANG Lei,CHEN Yan,JIA Shaodong,et al.Shaking table test and analysis on the seismic performance of pillarless large-span metro station[J].J. Xi'an Univ. of Arch. & Tech.(Natural Science Edition),2020,52(05):672-683.[doi:10.15986j.1006-7930.2020.05.009 ]
点击复制

无柱大跨地铁车站抗震性能试验与分析()
分享到:

西安建筑科技大学学报(自然科学版)[ISSN:1006-7930/CN:61-1295/TU]

卷:
52
期数:
2020年05期
页码:
672-683
栏目:
出版日期:
2020-10-28

文章信息/Info

Title:
Shaking table test and analysis on the seismic performance of pillarless large-span metro station
文章编号:
1006-7930(2020)05-0674-10
作者:
杨 磊1陈 雁1贾少东1胡双平2李江乐3
(1.南宁轨道交通集团公司,广西 南宁 530029; 2.中铁第一勘察设计院集团有限公司, 陕西 西安 710043; 3.西安建筑科技大学 土木工程学院,陕西 西安 710055)
Author(s):
YANG Lei1CHEN Yan1JIA Shaodong1HU Shuangping2 LI Jiangle3
(1.Nanning Rail Transit Co., Ltd., Nanning 530029, China;
关键词:
地下工程 无柱变截面地铁车站 振动台试验 地震响应
Keywords:
underground engineering pillarless variable section subway station shaking table test seismic response
分类号:
U 231+.4
DOI:
10.15986j.1006-7930.2020.05.009
文献标志码:
A
摘要:
无柱大跨地铁车站具有美观、方便、实用等优势,由于其结构形式取消了中柱,其抗震性能的可靠性也因此备受关注.为研究无柱大跨地铁车站在多种工况下的地震反应,本文以南宁某无柱支撑地下地铁车站为工程背景,对模型结构的相似比、模型材料进行相关的设计并选用地震波El-Centro波、Taft波、南宁人工波,开展了现浇式无柱变截面地铁车站模型的振动台试验研究.基于动力模型试验建立了有限元模型,分析了结构在地震波作用下的振动响应.最终研究成果表明:应力集中大多出现在结构的底、顶板和侧墙连接部位以及中板两侧靠近板墙的连接处,建议在工程应用中针对这些结构部位采取合理措施进行局部加强.
Abstract:
The pillarless large-span subway station has the advantages of being beautiful, convenient and practical. Due to the elimination of the center column in its structural form, the reliability of its seismic performance has also received much attention. In order to study the seismic response of the pillarless large-span subway station under various conditions, a pillarless-supported underground subway station in Xi'an is chosen as the engineering background. The similarity ratio of model structure and model materials were designed. The shaking table experiment was carried out, considering El-Centro wave, Taft wave, and Xi'an artificial wave. Based on the dynamic model test, the finite element analysis of the structure was made to study the vibration response of the structure under seismic waves. Results show that the stress concentration of the structure appears at the joints of the bottom of the station, at the roof and the side wall and the joints of the two sides of the middle plate near the wall. It is recommended to take reasonable measures for local strengthening of these structural parts in engineering applications.

参考文献/References:

[1] 施仲衡. 地下铁道设计与施工[M]. 西安: 陕西科学技术出版社, 1997. SHI Zhongheng. Underground railway design and construction [M].Xi'an: Shaanxi Science and Technology Press, 1997.
[2] 聂永明, 刘明保, 李志文. 地铁明挖区间无柱大空间结构体系的研究[J]. 建筑科学, 2012, 28(7):71-74. NIE Yongming, LIU Mingbao, LI Zhiwen. Structural System Research of Subway Non-Column-Supported Large Spacefor Open Excavated Tunnel[J]. Building Science, 2012, 28(7):71-74.
[3] 刘明保, 宫剑飞, 乐贵平, 等. 明挖区间隧道无柱大空间预应力结构设计[J]. 岩土工程学报, 2010(S2):371-374. LIU Mingbao, GONG Jianfei, LE Guiping, et al. Prestressed structural design of no-column-supported large space for open excavated tunnels[J]. Chinese Journal of Geotechnical Engineering, 2010(S2):371-374.
[4] HASHASH Y M A, HOOK J J, SCHMIDT B, et al. Seismic design and analysis of underground structures[J]. Tunnelling & Underground Space Technology Incorporating Trenchless Technology Research, 2001, 16(4):247-293.
[5] 王秀英, 刘维宁, 张弥. 地下结构震害类型及机理研究[J]. 中国安全科学学报, 2003, 13(11):55. WANG Xiuying, LIU Weining, ZHANG Mi. Study on the Categorization and Mechanism of Seismic Damageof Underground Structures[J]. China Safety Science Journal, 2003, 13(11):55.
[6] 郑永来. 地下结构抗震[M]. 同济大学出版社, 2005. ZHENG Yonglai, Underground structure earthquake resistance[M]. Tongji University Press, 2005.
[7] AN Xuehui, SHAWKY A A, MAEKAWA K. Collapse mec-hanism ofa subway station during the great Hanshin earthquake[ J].Cement and Concrete Composites, 1997, 19(3): 241- 257.
[8] 曹炳政, 罗奇峰, 马硕, 等. 神户大开地铁车站的地震反应分析[J]. 地震工程与工程振动, 2002, 22(4):102-107. CAO Bingzheng, LUO Qifeng, MA Shuo, et al. Seismic response analysis of Dakai subway stationin Hyogoken-nanbu earthquake[J]. Earthquake Engineering and Engineering Vibration, 2002, 22(4):102-107.
[9] 杜修力, 李洋, 许成顺, 等. 1995年日本阪神地震大开地铁车站震害原因及成灾机理分析研究进展[J]. 岩土工程学报, 2018, 40(2):223-236. DU Xiuli, LI Yang, XU Chengshun, et al. Review on damage causes and disaster mechanism of Daikai subway station during 1995 Osaka-Kobe earthquake[J]. Chinese Journal of Geotechnical Engineering, 2018, 40(2):223-236.
[10]庄海洋, 陈国兴, 王修信. 软土层厚度对地铁车站结构地震反应的影响规律研究[J]. 地震工程与工程振动, 2008, 28(6):245-253:223-236. ZHUANG Haiyang, CHEN Guoxing, WANG Xiuxin. Study on the influence law of soft soil layer thickness on seismic response of metro station structure[J]. Earthquake Engineering and Engineering Vibration, 2008, 28(6):245-253.
[11]庄海洋, 王雪剑, 陈国兴. 土-地铁动力相互作用体系侧向变形特征研究[J]. 岩土工程学报,2017,39(10):1761-1769. ZHUANG Haiyang, WANG Xuejian, CHEN Guoxing. Study on lateral deformation characteristics of soil-metro dynamic interaction system[J]. Journal of Rock Mechanics and Engineering, 2017,39(10):1761-1769.
[12]OHTOMO Keizo, SUEHIRO Toshio, KAWAI Tadashi, et al. Research on streamlining seismic safety evaluation of underground reinforced concrete duct-type structures in nuclear power stations.-Part2. Experimental aspects of laminar shear sand box excitation test with embedded RC models[C]// Transactions, SMiRT 16, Washington DC, Washington DC: ASMIRT, 2001.
[13]谷音, 钟华, 卓卫东. 地震作用下大型地铁车站结构三维动力反应分析[J]. 岩石力学与工程学报, 2013, 32(11):2290-2299. GU Yin, ZHONG Hua, ZHUO Weidong. Three-dimensional dynamic response analysis of large metro station structures under earthquake[J]. Journal of Rock Mechanics and Engineering, 2013, 32(11):2290-2299.
[14]杨林德, 季倩倩, 郑永来, 等. 软土地铁车站结构的振动台模型试验[J]. 现代隧道技术, 2003, 40(1):7-11. 37(4):421-427. YANG Linde, JI Qianqian, ZHENG Yonglai. Shaking table test on metro station structures in soft soil[J]. Modern tunnel technology, 2003, 40(1):7-11.
[15]王兰民, 刘琨, 孙军杰. 饱和原状黄土液化基本特征的振动台试验研究[J]. 地震工程学报, 2015(4):1023-1028. WANG Lanmin, LI Kun, SUN Junjie. Shaking table test liquefied saturated intact loess essential characteristics[J]. Journal of Earthquake Engineering, 2015(4):1023-1028.
[16]谌凯. 基于振动台模型试验的地铁车站结构地震反应研究[D].福州: 福州大学,2014. CHEN Kai. Research on the seismic responses of subway station based on shaking table test[D]. Fuzhou: Fuzhou University, 2014.
[17]谷音, 谌凯, 吴怀强, 等. 考虑地震动空间非一致性的地铁车站结构振动台试验研究[J]. 振动与冲击,2017,36(17):255-261,266. GU Yin, ZHAN Kai, WU Huaiqiang, et al. Shaking table tests for a subway station structure under spatiallynon-uniform ground motion[J]. Journal of Vibration and Shock, 2017,36(17):255-261,266.
[18]刘庭金, 许炜星, 唐欣薇. 上软下硬地层大跨无柱地铁车站地震响应分析[J]. 隧道建设, 2017, 37(S2):26-34. LIU Tingjin, XU Weixing, TANG Xinwei. Seismic response analysis of large-span pillarless metro station in upper soft and hard stratum[J]. Tunnel Construction, 2017, 37(S2):26-34.
[19]刘庭金, 郑月昱, 林伟波. 有、无柱地铁地下车站地震响应对比分析[J]. 隧道建设, 2017, 37(4):421-427. LIU Tingjin, ZHENG Yuehao, LIN Weibo, Comparative analysis of seismic response of underground stations with and without pillars[J]. Tunnel construction, 2017, 37(4):421-427.
[20]张亚辉, 赵岩, 张春宇. 大跨度桥梁抗震分析的空间效应[J]. 中国铁道科学,2002(6):92-96. ZHANG Yahui, ZHAO Yan, ZHANG Chunyu. Spatial effect of seismic analysis of long-span bridges[J]. China Railway Science, 2002(6):92-96.
[21]CHE A, IWATATE T, GE X. Dynamic behaviors of subway structure subjected to strong earthquake motions using shaking table tests and dynamic analyses[J]. Rock And Soil Mechanics, 2006, 27(8): 1293.
[22]TOMARI Y,TOWHATA I. Soil-structure interaction of cross sections of flexible underground structures subjected to soil liquefaction[J]. Soils and Foundations, 2003, 43(2): 69-87.
[23]JAFARZADEH F,FARAHI H,ABAZARI E. Investigating dynamic response of a buried pipeline in sandy soil layer by 1g shaking table test[J]. International Journal of Civil Engineering, 2010, 8(2): 107-124.
[24]KOSEKI J,MATSUO O,KOGA Y. Uplift behavior of underground structures caused by liquefaction of surrounding soil during earthquake[J]. Soils and Foundations,1997, 37(1): 97-108.
[25]YASUDA S,NAGASE H, ITAFUJI S,et al. Shaking table tests on floatation of buried pipes due to liquefaction of backfill sands[C]// Proceedings of the 5th US-Japan Workshop Earthquake Resistance Design of Lifeline Facilities and Countermeasures against Soil Liquefaction, Utah. Buttalo: Technical Report Nceer, 1994:655-677,1995.

备注/Memo

备注/Memo:
收稿日期:2019-03-13 修改稿日期:2020-09-15
基金项目:国家自然科学基金资助项目(51178388); 陕西省教育厅点实验室科研计划基金资助项目(11JS059,12JS055)
第一作者:杨 磊(1983-),男,硕士,高级工程师,主要从事隧道及地下工程研究.E-mail: 120403560@qq.com

更新日期/Last Update: 1900-01-01