干热干冷地区室外综合温度计算模型适用性分析

(西安建筑科技大学 建筑学院,陕西 西安 710055)

室外综合温度; 长波辐射换热; 围护结构得热; 数值模拟

Research on the applicability of sol-air temperature calculation model in dry-hot and dry-cold areas
CHEN Jie,LUO Zhixing,YANG Liu

(School of Architecture,Xi'an Univ. of Arch. & Tech.,Xi'an 710055,China)

sol-air temperatures; long-wave radiation exchange; building envelope heat gain; numerical simulation

DOI: 10.15986/j.1006-7930.2021.03.016

备注

室外综合温度对建筑负荷计算和围护结构热工设计十分重要,为评价室外综合温度计算模型在干热干冷地区的适用性,以吐鲁番作为干热干冷地区代表城市,同时选取西安、拉萨、上海作为对比对室外综合温度计算模型差异进行分析.同时采用数值模拟计算了一栋简化居住建筑的模型计算误差.结果表明,两种模型在不同气候下均存在差异,干热干冷地区差异最显著,西安和上海地区可采用空气温度做室外综合温度简化计算,吐鲁番和拉萨地区应采用天空辐射值对室外综合温度进行计算.
Sol-air temperatures are very important to the thermal load calculation and building envelope structure design. To evaluate applicability of the sol-air temperatures calculation model for dry hot and dry cold areas,the paper takes Turpan as the representative city,with Shanghai and Xi'an,Lhasa as a comparison to analyze the differences of sol-air temperatures calculation models. The model error of a simplified residential building is calculated by numerical simulation. The results show that the differences exist in two models in different climates,which are remarkable in dry hot and dry cold areas. Air temperature can be used for the simplified calculation of sol-air temperatures in Xi'an and Shanghai,and sky radiation value should be used for the calculation of sol-air temperatures in Turpan and Lhasa.