[1]熊仲明,黄汉英,虞子良,等.带限位装置的基础隔震结构反应谱研究[J].西安建筑科技大学学报(自然科学版),2017,49(02):172-178.[doi:10.15986/j.1003-7930.2017.02.003]
 XIONG Zhongming,HUANG Hanying,YU Ziliang,et al.Response spectra of base-isolated structure with limiting stopper[J].J. Xi’an Univ. of Arch. & Tech.(Natural Science Edition),2017,49(02):172-178.[doi:10.15986/j.1003-7930.2017.02.003]
点击复制

带限位装置的基础隔震结构反应谱研究()
分享到:

西安建筑科技大学学报(自然科学版)[ISSN:1006-7930/CN:61-1295/TU]

卷:
49
期数:
2017年02期
页码:
172-178
栏目:
出版日期:
2017-04-28

文章信息/Info

Title:
Response spectra of base-isolated structure with limiting stopper
文章编号:
1006-7930(2017)02-0172-07
作者:
熊仲明1黄汉英1虞子良2陈 轩1
(1.西安建筑科技大学土木工程学院,陕西 西安 710055 ;2. 深圳市建筑设计研究总院,广东 深圳 518031 ;)
Author(s):
XIONG Zhongming1 HUANG Hanying1 YU Ziliang2 CHEN Xuan1
(1. College of Civil Engineering, Xian Univ. of Arch . & Tech ., Xian 710055 2. Shenzhen General Institute of Architectural Design and Research Co., Ltd, Shenzhen 518031)
关键词:
并联基础隔震结构地震反应谱摩擦系数及阻尼比远、近场地震
Keywords:
base-isolated structure seismic response spectra friction coefficient and damping ratio far-near earthquake
分类号:
TU 352.1
DOI:
10.15986/j.1003-7930.2017.02.003
文献标志码:
A
摘要:
带限位装置的并联基础隔震体系具有摩擦耗能及限位的能力,其隔震效果明显.通过单自由度并联基础隔震结构模型,研究了结构体系摩擦系数及阻尼比对加速度谱和隔震层位移谱的影响,建立了不同类场地的远、近场地震作用下地震影响系数谱及隔震层位移谱,采用时程分析、隔震结构反应谱及规范反应谱分别对实际工程进行了计算,得到并联基础隔震结构层间剪力及层间位移的差异。研究表明,场地类别及地震动特性对基础隔震结构反应谱影响作用较大;隔震结构反应谱计算数值与时程分析结果相近,而规范反应谱计算结果偏大,说明规范反应谱用于基础隔震结构的设计与计算需进行相应的系数折减.研究成果可为基础隔震结构反应谱在实际工程中的应用提供参考依据.
Abstract:
Based-isolated structure with limiting stopper have the capacity of energy consuming and limiting, which isolated effect is obvious. By the base-isolated structure model of the single degree of freedom, the paper analyzed the friction coefficient and damping ratio influence on the spectra of acceleration and isolation la yer displacement, then, established the spectra of seismic influence coe fficient and isolation layer displacement under the far-near earthquake and results show ed that the type of seismic field and characte ristics of ground motion have a big impact on isolated structure response spectra. Finally, the study compared the layer shear force and displacement that calculated by the time-history analysis, isolated structure response spectra and standard response spectra. The calculated results of isolated response spectra and time-history analysis were nearly close. However, numerical results of the standard response spectra would be larger, which means corresponding coefficients of response spectra should have a reduction if the standard response spectra was applied for base-isolated structure design and calculation. The results can put forward for base-isolated structure response spectra applied on the real construction.
更新日期/Last Update: 2017-06-08