参考文献/References:
References
[1] 康艳兵, 江亿, 张寅平. 夜间通风相变贮能吊顶系统实验分析[J]. 建筑学报, 2002(7): 32-34.
KANG Yanbing, JIANG Yi, ZHANG Yinping. Experimental analysis of phase change and stored energy ceiling system for night ventilation[J]. Architectural Journal, 2002(7): 32-34.
[2] 张璞. 夜间通风相变储能材料的适宜性研究[D]. 西安: 西安建筑科技大学, 2013.
ZHANG Pu. Suitability of phase change materials for night ventilation cooling technique[D]. Xi’an: Xi’an Univ. of Arch. & Tech., 2013.
[3] 朱新荣. 北方办公建筑夜间通风降温研究[D]. 西安: 西安建筑科技大学, 2010.
ZHU Xinrong. Night ventilation cooling technique research of office building in northern China[D]. Xi’an: Xi’an Univ. of Arch. & Tech., 2010.
[4] 杨茜, 杨柳, 刘加平. 西安市夏季住宅室内热舒适调查研究[J]. 制冷与空调, 2011(1): 49-59.
YANG Qian, YANG Liu, LIU Jiaping. Field study on thermal comfort in summer of Xi’an urban residence buildings[J]. Refrigeration and Air Conditioning, 2011(1): 49-59.
[5] 冯国会, 韩淑伊, 刘馨, 等. 相变墙房间夏季夜间通风效果实验[J]. 沈阳建筑大学学报: 自然科学版, 2013, 29(4): 693-697.
FENG Guohui, HAN Shuyi, LIU Xin, et al. Experimental study on night ventilation effect in a phase change wall room in summer[J]. Journal of Shenyang Jianzhu University: Natural Science, 2013, 29(4): 693-697.
[6] LE D J, HEISELBERG P, JENSEN R L. Experimental investigation of convective heat transfer during night cooling with different ventilation systems and surface emissivities[J]. Energy and Buildings, 2013, 61: 308-317.
[7] FENG Guohui, CHEN Qizhen, HUANG Kailiang, et al. Cool storage time of phase change wallboard room in summer[J]. Journal of Central South University, 2010(S1): 75-79.
[8] HUANG Kailiang, FENG Guohui, CHEN Qizhen, et al. Storage and exchange thermal characteristic analysis of phase change wallboard[J]. Journal of Central South University, 2010(S1): 154-158.
[9] RUUD M, MITCHELL J, KLEIN S, The role of thermal mass on the cooling load of buildings[J]. ASHRAE Trans, 1990, 96(2): 820-835.
[10] GEROS V, SANTAMOURIS M, TSANGRASOULIS A, et al. Experimental evaluation of night ventilation phenomena[J]. Energy and Buildings, 1999, 29(2): 141-154.
[11] GEROS V, SANTAMOURIS M, KARATASOU S, et al. On the cooling potential of night ventilation techniques in the urban environment[J]. Energy and Buildings, 2005, 37(3): 243-257.
[12] KUBOTA T, HOOICHYEE D T, AHMAD S. The effects of night ventilation technique on indoor thermal environment for residential buildings in hot-humid climate of Malaysia[J]. Energy and Buildings, 2009, 41(8): 829-839.
[13] SANTAMOURIS M, SFAKIANAKI A, PAVLOU K. On the efficiency of night ventilation techniques applied to residential buildings[J]. Energy and Buildings, 2010, 42(8): 1309-1313.
[14] WANG Zhaojun, YI Lingli, GAO Fusheng. Night ventilation control strategies in office buildings[J]. Solar Energy, 2009, 83(10): 1902-1913.
[15] ZHOU Guobing, YANG Yongping, XU Hong. Energy performance of a hybrid space-cooling system in an office building using SSPCM thermal storage and night ventilation[J]. Solar Energy, 2011, 85(3): 477-485.
相似文献/References:
[1]朱新荣,杨 雯,杨 柳,等.夜间通风建筑关键设计参数优化分析[J].西安建筑科技大学学报:自然科学版,2016,48(03):401.[doi:10.15986/j.1006-7930.2016.03.016]
ZHU Xinrong,YANG Wen,YANG Liu,et al.Optimization on critical design parameter of night ventilation buildings[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2016,48(05):401.[doi:10.15986/j.1006-7930.2016.03.016]