[1]王宇,李婉,何发龙.绿色公共建筑运行能耗特征分析及能效评估[J].西安建筑科技大学学报(自然科学版),2017,49(04):565-572.[doi:10.15986/j.1006-7930.2017.04.017]
 WANG Yu,LI Wan,HE Falong.Operation energy consumption characteristics analysis and energy efficiency evaluation of green public building[J].J. Xi’an Univ. of Arch. & Tech.(Natural Science Edition),2017,49(04):565-572.[doi:10.15986/j.1006-7930.2017.04.017]
点击复制

绿色公共建筑运行能耗特征分析及能效评估()
分享到:

西安建筑科技大学学报(自然科学版)[ISSN:1006-7930/CN:61-1295/TU]

卷:
49
期数:
2017年04期
页码:
565-572
栏目:
出版日期:
2017-09-10

文章信息/Info

Title:
Operation energy consumption characteristics analysis and energy efficiency evaluation of green public building
文章编号:
1006-7930(2017)04-0565-08
作者:
王宇李婉何发龙
( 天津城建大学 能源与安全工程学院,天津 300384 )
Author(s):
WANG Yu1 LI Wan1 HE Falong1
(1. School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China)
关键词:
能耗监测能效系数输送系数能耗模拟
Keywords:
energy consumption monitoring energy efficiency transmission coefficient energy consumption simulation
分类号:
TU83
DOI:
10.15986/j.1006-7930.2017.04.017
文献标志码:
A
摘要:
为有效把握我国寒冷地区绿色公共建筑运行能耗特征及运行能效水平,以天津生态城公屋展示中心为研究对象,通过运营阶段实时监测数据,掌握案例建筑能耗结构、不同季度各分项能耗分布、系统季节能效系数、热泵机组能效系数、循环水泵输送系数等能耗指标,并从机组的启停时序及供回水温差两方面优化案例建筑运行,分析其节能潜力.分析整理实时监测数据可知,采暖季建筑能耗占全年能耗比例最大达 63% ,此时段建筑耗电量达 77% ;热泵系统夏季能效比为 5 .77,冬季能效比为 3 .53;冷冻水循环水泵冬季输送系数为 35 .29、夏季输送系数为 58 .85;利用模拟工具对采用优化方案后建筑运行能耗进行运行效果分析可知,控制机组启停时序总能耗降低 27 .2%,在此基础上提高系统供回水温差总能耗可降低 30 .8%
Abstract:
In order to effectively grasp the energy consumption characteristics and operational energy efficiency of green public buildings in cold areas of China, this paper takes the Tianjin Eco -City Public Housing Exhibition Center as the research object, realizes the data through the operation phase, controls the energy consumption structure of the case building, energy consumption distribution, energy efficiency coefficient of the system, energy efficiency coefficient of the heat pump unit, and the transport coefficient of the circulating water pump, to optimize the case building operation from the aspects of the start and stop timing of the unit and the supply and return temperature. Through analysis and finishing real -time monitoring data it can be seen that the energy consumption of the building season accounted for the largest annual energy consumption up to 63%, with electricity consumption of 77% at the time. Heat pump system summer energy efficiency ratio of 5.77, and winter energy efficiency ratio of 3 .53. The winter transmission coefficient of the chilled water circulating pump is 35 .29 and the summer transmission coefficient is 58.85. The simulation results show that total energy consumption of the control unit is reduced by 27 .2%, and the system is provided on the basis of the simulation tool. The total energy consumption of the water temperature difference can be reduced by 30 .8%

参考文献/References:

References

[1]程世丹,喻斯文,尹卫民.大型绿色公共建筑节能绩效后评估研究:以武汉“市民之家”建筑为例[J].动感(生态城市与绿色建筑),2015(2):102-107.

CHENG Shidan,YU Siwen,YIN Weimin. Study on the performance evaluation of large green public building energy effciency:taking Wuhan “Citizen′s Home” building as an example [J].Dynamic (Eco City and Green Building), 2015(2):102-107 .

[2]汪飞宇.夏热冬冷地区办公建筑能效评估典型方法研究[D].合肥: 安徽建筑工业学院,2012.

WANG Feiyu. Study on typical methods of energy efficiency evaluation for office buildings in hot summer and cold winter zone [D].Hefei: Anhui Institute of Architecture and Industry, 2012.

[3]李丛笑,林波荣.我国绿色建筑使用效果后评估实践[J].动感(生态城市与绿色建筑),2015(1) :53-58.

LI Congxiao,LIN Borong. China′s green building use effect evaluation practice [J]. Dynamic (Eco City and Green Building), 2015(1) :53-58.

[4]中华人民共和国住房和城乡建设部.国家标准GB/T50378-2014《绿色建筑评价标准》将于2015年起实施[J].建筑科学,2014(6):65.

Ministry of Housing and Urban-Rural Construction of the People′s Republic of China. National standard GB/T50378 -2014 “green building evaluation standards” will be implemented in 2015[J]. Building Science,2014(6):65.

[5]林波荣,刘彦辰,裴祖峰.我国绿色办公建筑运行能耗及室内环境品质实测研究[J]. 暖通空调,2015,45(3):1-8.

LIN Borong,LIU Yanchen,PEI Zufeng. Research on energy consumption and indoor environment quality of green office building in China [J]. HVAC, 2015 ,45(3):1-8.

[6]肖娟.绿色公共建筑运行性能后评估研究[D].北京:清华大学,2013.

XIAO Juan. Study on Post - evaluation of Green Public Building Operation Performance [D].Beijing: Tsinghua University, 2013.

[7]TURNER Cathy, FRANKEL Mark. Energy performance of LEED for new construction buildings [R]. Washington: Energy Performance of LEED Buildings,2008 : 15 -19,28-31.

[8]SCOFIELD John H. Do LEED -certified buildings save energy? Not really Energy and Buildings[J]. 2009, 41: 1386-1390.

[9]FARD Abbaszadeh. Occupant satisfaction with indoor environmental quality in green buildings [J].Healthy Buildings,2006,111:365-370.

[10]RADHI Hassan. A systematic methodology for optimizing the energy performance of buildings in Bahrain [J]. Energy and Buildings, 2008, 40(7): 1297-1303.

[11]伍小亭.超低能耗绿色建筑设计方法思考与案例分析:以中新天津生态城公屋展示中心为例[J].建设科技,2014(22):58-65.

WU Xiaoting . Thinking and case study of green building design method for ultra -low energy consumption:taking Zhongxin Tianjin ecological city public housing exhibition center as an example [J]. Construction technology,2014(22) :58-65.

[12]屠雪临.天津中新生态城公屋展示中心的被动节能方案分析[J].绿色建筑,2013(1) :20-23.

TU Xuelin. Analysis on passive energy -saving scheme of Tianjin Zhongxin ecological city public housing exhibition center [J].Green Building, 2013(1) :20-23.

[13]郑福居,魏慧娇,孙晓峰,等.中新天津生态城公屋展示中心绿色建筑节能技术探讨[J].建设科技,2012(20):46-49.

ZHENG Fuju,WEI Huijiao,SUN Xiaofeng,et al. Discussion on green building energy saving technology of Zhongxin Tianjin eco city public housing exhibition center [J]. Construction technology, 2012(20 ) :46-49.

[14]周锐.寒冷地区零能耗公共建筑运行研究[D].天津:天津大学,2013.

ZHOU Rui. Study on zero energy consumption public building operation in cold area [D].Tianjin: Tianjin University,2013.

[15]肖丹.公共建筑能耗分析的数据挖掘方法研究与系统开发[D].重庆:重庆大学,2012.

相似文献/References:

[1]刘 丹.大型公共建筑能耗监测平台及监管模式[J].西安建筑科技大学学报(自然科学版),2014,46(01):96.[doi:10.15986/j.1006-7930.2014.01.017]
 LIU Dan.Energy consumption monitor platform and regulation system for large public buildings[J].J. Xi’an Univ. of Arch. & Tech.(Natural Science Edition),2014,46(04):96.[doi:10.15986/j.1006-7930.2014.01.017]
[2]刘 丹,李安桂,叶 红.基于能耗监测系统的建筑节能管理模式研究[J].西安建筑科技大学学报(自然科学版),2011,43(02):281.[doi:DOI :10.15986/j .1006-7930.2011.02.026]
 LIU Dan,LI An-gui,YE Hong.Research on energy consumption monitor system-based managerial mode of building energy thrift[J].J. Xi’an Univ. of Arch. & Tech.(Natural Science Edition),2011,43(04):281.[doi:DOI :10.15986/j .1006-7930.2011.02.026]

备注/Memo

备注/Memo:
收稿日期:2016-10-09修改稿日期:2017-7-11
基金项目:住房和城乡建设部研究开发项目(2016-R1-008)
第一作者:王宇(1980-),男,博士,副教授,主要研究建筑节能与可再生能源综合利用、暖通空调系统测量控制.E-mail: 18142232383@163.com