[1]李 翠,李峥嵘,赵 群.既有高层玻璃幕墙建筑遮阳卷帘的调节规律研究[J].西安建筑科技大学学报:自然科学版,2013,45(01):86-91.[doi:10.15986/j.1006-7930.2013.01.013]
 LI Cui,LI Zheng-rong,ZHAO Qun.Research on roller blind behavior for high-rising glass curtain buildings in Shanghai[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2013,45(01):86-91.[doi:10.15986/j.1006-7930.2013.01.013]
点击复制

既有高层玻璃幕墙建筑遮阳卷帘的调节规律研究()
分享到:

西安建筑科技大学学报:自然科学版[ISSN:1006-7930/CN:61-1295/TU]

卷:
45
期数:
2013年01期
页码:
86-91
栏目:
出版日期:
2013-02-28

文章信息/Info

Title:
Research on roller blind behavior for high-rising glass curtain buildings in Shanghai
文章编号:
1006-7930(2013)01-0086-06
作者:
李 翠1李峥嵘1赵 群2
(1.同济大学机械与能源工程学院,上海 200092;2.同济大学建筑与城市规划学院,上海 200092)
Author(s):
LI Cui LI Zheng-rong ZHAO Qun
(1.College of Mechanical and Energy Engineering, Tongji University, Shanghai 200092,China; 2.College of Architecture and Urban Planning, Tongji University, Shanghai 200092,China)
关键词:
高层幕墙建筑建筑遮阳调节卷帘
Keywords:
high-rising glass curtain building shading adjust roller
分类号:
TU86
DOI:
10.15986/j.1006-7930.2013.01.013
文献标志码:
A
摘要:
重点分析了上海9幢高层玻璃幕墙建筑遮阳的全年使用规律,提出 “ 卷帘使用状态特征值Y”的概念,用于定量化研究遮阳的使用规律及其对空调负荷的影响.结果显示,上海既有高层玻璃幕墙建筑的遮阳设施以内遮阳卷帘为主,各遮阳帘Y值的分布较分散,呈现明显的随机性.而且,遮阳卷帘的调节规律受到窗户朝向、季节和时间的影响.遮阳卷帘的日调节主要集中在上下班和午休时间.在同一季节内,东南向日平均调节比例相对较高,北向则较低;北向遮阳日平均调节比例较高的季节是春季,东北向和东南向则是夏季.在季节转换后,超过25%的卷帘将发生季节性调节,其中以东南向窗户最为显著;春季转向夏季后,遮阳帘的季节性调节比例高于冬季转向春季后的比例.考虑特征值Y时,不同朝向,夏季设计日空调累计负荷与不考虑时的相差20%~27%,后者扩大了实际遮阳使用状态下的节能效果
Abstract:
Shading products in nine high-rising glass-curtain buildings are studied to find out its running behavior. A new characteristic value “Y” is defined to quantify the roller blind’s running status. Results show that interior roller blind is the main shading product used for Shanghai’s existing high-rising glass—curtain buildings, and the separate distribution of the Y value refers to the randomness of the use of the rollers. Further research shows that the facade aspect, time and season will affect the roller use. The daily adjusting action mainly happens when occupants arrive first time or leave office last, and when they have a rest during noon. During a fixed season, the daily adjusted ratio for rollers facing south-east is higher than that for others. The highest daily adjusted ratio for rollers facing north happens in spring, while in summer for those facing south-east and north-east. More than 25% of the rollers will be adjusted after the season changes, especially for the rollers facing south-east. The total adjusted ratio of rollers is bigger when the season changes from spring to summer than that from winter to spring. This paper suggests that ignoring the running behavior of the rollers will result in magnifying the energy saving from shading products.

参考文献/References:

[1] 罗 涛.玻璃幕墙建筑的室内外天然光环境研究[D].北京:清华大学建筑学院,2005.
LUO Tao.Study on the indoor and outdoor daylight environment of glass curtain wall buildings[D].Beijing:School of architecture,Tsinghua University,2005.
[2] 李峥嵘,赵 群,展 磊.建筑遮阳与节能[M].北京:中国建筑工业出版社,2009.
LI Zheng-rong,ZHAO Qun,ZHANG Lei.Solar Shading and Energy Conservation[M].Beijing: China Building industry Press,2009.
[3] 杨慧媛,高甫生.玻璃类型对玻璃幕墙建筑室内热环境的影响分析[J].暖通空调,2005,35(10):23-28
YANG Hui-yuan,GAO Pu-sheng.Analyses of the effect of glass types on indoorthermal environment in glass curtain buildings[J].HV&AC,2005,35(10):23-28.
[4] GB50189-2005,公共建筑节能设计标准[S].北京:中国建筑工业出版社,2005.
GB50189-2005,Design standard for energy efficiency of public building[S].Beijing:China Building Industry Press, 2005.
[5] VorapatInkarojrit.Balancing Comfort:OccupantsControl of Window Blinds in Private Offices. Doctor of Philosophy in Architecture in the GRADUATEDIVISION of the UNIVERSITY OF CALIFORNIA,BERKELEY,2005.
[6] Haydar Sukru Tokel.User Control Actions in Buildings:A Case Study of Shading[J].MSc Program“Building Science &Technology”,Vienna,2006.
[7] CF Reinhart DrIng,K Voss DrIng.Monitoring manual control of electric lighting and Blinds[J].Lighting Res.Technol,2003,35(3):243-260.
[8] Ardeshir Mahdavi,AbdolazimMohammadi.Occupantsoperation of lighting and shading systems in office buildings[J].Journal of Building Performance Simulation,2008(3):57-65.
[9] ZHANG Yu-fan,Peter Barrett.Factors influencing occupantsblind-control behaviour in a naturally ventilated office building[J].Building and Environment, 2012(54): 137-147.
[10] Christoph F Reinhart.Lightswitch-2002:a model for manual and automated control of electric lighting and blinds[J].Solar Energy,2004,77:15-28.
[11] JIAN Yao.An Investigation of Adjustment of Solar ShadingDevices in Office Buildings[J].World Academy of Science,Engineering and Technology,2011.
[12] Abdolazim Mohammadi,ElhamKabir.MODELING USER CONTROL OF LIGHTING AND SHADING DEVICES IN OFFICE BUILDINGS[J].AN EMPIRICAL CASE STUDY,Building Simulation,2007: 772-778
[13] 陆亚俊,马最良,皱平华.暖通空调[M].2版.北京:中国建筑工业出版社,2007.
LU Ya-jun,MA Zui-liang,ZHOU Ping-hua.HV&AC [M].second edition.Beijing:China building industry press,2007.
[14] 潘欣钰.卷帘和软百叶遮阳性能研究[D].上海:同济大学,2012.
PAN Xin-yu.Research on Shading Performance of Rollers and Blinds Made by Soft Materials[D].Shanghai:Tongji University,2012.

相似文献/References:

[1]刘加平,罗戴维,刘大龙.湿热气候区建筑防热研究进展[J].西安建筑科技大学学报:自然科学版,2016,48(01):1.[doi:10.15986/j.1006-7930.2016.01.001]
 LIU Jiaping,LUO Daiwei,LIU Dalong.Review of building thermal protection in the hot and humid climate[J].J.Xi’an Univ. of Arch. & Tech.:Natural Science Edition,2016,48(01):1.[doi:10.15986/j.1006-7930.2016.01.001]

备注/Memo

备注/Memo:
收稿日期:2012-09-17 修改稿日期:2013-01-04
基金项目:中美清洁能源联合研究中心建筑节能合作项目(2010DFA72740)
作者简介:李 翠(1982-),女,上海人,博士研究生,主要从事建筑节能方面研究.
更新日期/Last Update: 2015-10-05