[1]张群,于卓玉,成辉,等.绥化地区地板辐射式采暖居住建筑冬季室内热舒适调查分析[J].西安建筑科技大学学报(自然科学版),2018,50(03):396-0401.[doi:10.15986/j.1006-7930.2018.03.013]
 ZHANG Qun,YU Zhuoyu,CHENG Hui,et al.Field study on occupant thermal comfort in radiant floor heating system residential buildings of Suihua city in winter[J].J. Xi’an Univ. of Arch. & Tech.(Natural Science Edition),2018,50(03):396-0401.[doi:10.15986/j.1006-7930.2018.03.013]
点击复制

绥化地区地板辐射式采暖居住建筑冬季室内热舒适调查分析()
分享到:

西安建筑科技大学学报(自然科学版)[ISSN:1006-7930/CN:61-1295/TU]

卷:
50
期数:
2018年03期
页码:
396-0401
栏目:
出版日期:
2018-06-30

文章信息/Info

Title:
Field study on occupant thermal comfort in radiant floor heating system residential buildings of Suihua city in winter
文章编号:
1006-7930(2018)03-0396-06
作者:
张群12于卓玉1成辉1梁锐3
( 1. 西安建筑科技大学 建筑学院,陕西 西安 710055; 2.苏州市建筑科研研究院院士工作站,江苏 苏州 215129;3. 西安美术学院 建筑环境艺术系,陕西 西安 710065 )
Author(s):
ZHANG Qun12 YU Zhuoyu1 CHENG Hui1 LIANG Rui3
(1.School of Architecture, Xi′an Univ. of Arch. & Tech., Xi′an 710055, China; 2. Academician Workstation of Suzhou Building Research Institute. Suzhou 215129,China; 3. Department of Architecture & Environment, Xi′an Fine Art Academy, Xi′an 710065, China)
关键词:
绥化地区 居住建筑 地板辐射式采暖 热舒适 热感觉
Keywords:
Suihua city residential buildings radiant floor heating system thermal sensation thermal comfort
分类号:
TU45
DOI:
10.15986/j.1006-7930.2018.03.013
文献标志码:
A
摘要:
为了研究严寒地区冬季采暖期居住建筑室内的热环境状况,以绥化地区地板热辐射式采暖住宅为例,调查了其室内热舒适现状,探讨了改善建筑室内热环境的方法,采用测试、问卷调查等方式和以ASHRAE的7级热感觉标度,对该类建筑冬季室内热舒适情况和热感觉主观反映进行统计分析.结果显示,该地区冬季地板热辐射采暖居住建筑室内温度偏高、居民的热期望温度为24.9 ℃、冬季80%可接受的舒适温度范围为21.9~25.8 ℃.结合该地区特点,提出适合绥化地区地板辐射式采暖居住建筑冬季室内舒适温度区间为23~25 ℃,为改善当地住宅建筑节能设计提供依据.
Abstract:
To reveal the indoor thermal environment in winter heating period in severe cold regions, taking the residential buildings with radiant floor heating system in Suihua as the research object, the indoor occupant thermal comfort conditions of residents are explored and ways to improve the indoor thermal environment in Suihua are probed. A subjective questionnaire and a sevenpoint thermal sensation scale are used to evaluate the thermal sensation, and the data were studied with the statistical method. The results show that the temperature of residential buildings with the radiant floor heating system is higher in Suihua. The preferred temperature is 24.9 ℃,and the accepted temperature scope for 80% of the occupants is between 21.9 ℃ and 25.8 ℃. Combined with the characteristics of urban residents living in Suihua, the indoor comfortable temperature of residential buildings with the radiant floor heating system in Suihua ranged between 23 ℃ and 25 ℃ so that the necessary theoretical basis for residential energy saving design is provided to the designers.

参考文献/References:

[1]李俊鸽,杨柳,刘加平.夏热冬冷地区夏季住宅室内 适应性热舒适调查研究[J].四川建筑科学研究,2008,34(4):200-205.

LI Junge, YANG Liu, LIU Jiaping. Athermal comfort field survey in residential buildings in hot-summer and cold-winter area[J]. Building Science Research of Sichuan, 2008, 34(4):200-205.
[2]简毅文, 江亿. 现代居住建筑的夏季热状况研究——北京市住宅夏季室温调查分析[J]. 暖通空调, 2002,32(3):7-10.
JIAN Yiwen JIANG Yi.0 Evaluation of thermal performance of existing residential buildings in Beijing[J]. HVAC, 2002,32(3):7-10.
[3]刘大龙,刘加平,何泉,等银川典型季节传统民居热环境测试研究[J].西安建筑科技大学学报:(自然科学版),2010,42(1):83-86.
LIU Dalong, LIU Jiaping, HE Quan, et al. Investigation of thermal environment for Yinchuan traditional dwelling building in winter [J]. J. Xi′an Univ. of Arch. & Tech.,(Natural Science Edition),2010,42(1):83-86.
[4]王昭俊,方修睦,廉乐明.哈尔滨市区冬季居民热舒适现场研究[J].哈尔滨工业大学学报,2002,34(4):500-504.
WANG Zhaojun, FANG Xiumu, LIAN Leming. Field experiments on occupant thermal comfort in Harbin [J].Journal of Harbin Institute of Technology, 2002, 34(4):500-504.
[5]张旭,薛卫华,王宝凯,等.供暖房间热舒适模糊分析及最优室内计算温度的研究[J]. 暖通空调, 1999, 29(2):66-68.
ZHANG Xu, XUE Weihua, WANG Baokai, et al. Fuzzy analysis of thermal comfort and optimum indoor temperature in heated rooms [J]. HVAC, 1999, 29(2):66-68.
[6]赵会民,赵晓丽,宋清彦绥化市水文特征分析[J]. 黑龙江水专学报,2004,(12).
ZHAO Huimin, ZHAO Xiaoli, SONG Qingyan Analysis on hydrology characteristic of Suihua City [J].Journal of Heilongjiang Hydraulic Engineering College, 2004,12.
[7]International Organization for Standardization. Ergonomics of the thermal environment—analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria:ISO:ISO7730—2005[S]. Switzerland:Geneva, 2005.
[8]黄晨, 龙惟定. 建筑环境学[M].北京:机械工业出版社,2005.
HUANG Chen, LONG Weiding Built environment [M]. Beijing: China Machine Press,2005.
[9]金虹,赵华,王秀萍严寒地区村镇住宅冬季室内热舒适环境研究[J].哈尔滨工业大学学报,2006,38(12):2108-2111.
JIN Hong, ZHAO Hua, WANG Xiuping. Research on the indoor thermal comfort environment of rural housing in w inter in super-cold region[J].Journal of Harbin Institute of Technology, 2006,38(12):2108-2111.
[10]MCINTYRE D A. Indoor Climate [M]. London: Applied Science Published LTD, 1980.
[11]李百战,郑洁,姚润明,等. 室内热环境与人体热舒适[M].重庆:重庆大学出版社,2012.
LI Baizhan, ZHENG Jie, YAO Runming, et al. Indoor thermal environment and thermal comfort of human body[M].Chongqing:Chongqing University Press, 2012.
[12]杨茜. 寒冷地区室内热舒适研究[D]. 西安:西安建筑科技大学, 2010.
YANG Qian. Study on the indoor thermal comfort in the cold zone[D]. Xi′an: Xi′an Univ of Arch & Tech,2010.
[13]李俊鸽.  夏热冬冷地区人体热舒适气候适应模型研究[D]. 西安:西安建筑科技大学, 2006.
LI Junge.An adaptive thermal comfort model for hot summer and cold winter context[D]. Xi′an:Xi′an Univ of Arch & Tech,2006.
[14]李俊鸽, 杨柳, 刘加平.  夏热冬冷地区人体热舒适气候适应模型研究[J]. 暖通空调, 2008, 38(7):20-24.
LI Junge,YANG Liu,LIU Jiaping. Adaptive thermal comfort model for hot summer and cold winter zone[J]. HVAC, 2008, 38(7):20-24.
[15]景胜蓝. 自由运行建筑人体热适应性研究[D]. 重庆:重庆大学, 2013.
JING Shenglan. Human adaptation to thermal environment in free running building[D].Chongqing:Chongqing University, 2013.
[16]胡璘, 杨善勤 新编《民用建筑节能设计标准》内容介绍[J].建筑技术通讯(暖通空调) , 1987(5):3-6.
HU Lin, YANG Shanqin. New “Energy conservation design standard” Introduction[J].HVAC, 1987(5):3-6.

备注/Memo

备注/Memo:
收稿日期:2016-06-30修改稿日期:2017-11-09
基金项目:国家自然科学基金项目(51678466,51408465,51408474,51278414);吴中创新创业领军人才项目(WC201507)
第一作者:张群(1973-),男,博士,教授,主要研究绿色建筑及地域建筑研究.E-mail: zhangqun029@126.com